Using an insulation resistance range, measure and record this resistance reading. Connect conductor under test to the line terminal of the megger. Normally conducted on 600volt power cable for either acceptance or maintenance purposes, a megohm meter typically applies 600 to 2,500 v dc for several minutes to the cable. This test may be combined with the cable megger test by power testing the devices and terminated cables together. Step 6 touch either of the megohmmeters leads to the ground being used for that electrical system. That is, with the same test connections and with the same test voltage applied for the same length of time. Power cables with extruded insulation and their accessories for rated voltages from 1 kv um 1,2 kv up to 30 kv um 36 kv part 1.
The readings obtained from ir tests on nonshielded, nonmetallicsheathed cable are dependent upon the environment because it determines the characteristics. Megger testing nonshielded cables by applying a potential to the test cable and grounding the other cables on the same reel, in the same duct, as well as possibly the duct itself provides a real life example of a megger test that may produce marginal results due to the inherent lack of a. Rotate the handle of megger or press push button of megger. Test results as low as 10 megohms on old cable circuits are common and therefore considered safe to energies. The complete guide to electrical insulation testing. Sep 26, 2018 a megger is an ohmmeter that measures resistance in the megohm scale.
In this video we explain how to check cable insulation with megger or megaohm meter. Cable test vans 338 other megger products you may find useful 340 what cat ratings mean 341 about megger 342 environmental care and service 344 training local to you 345 index 346 for alphabetic index see page 346. Structured cable certification tests 2 next, attenuation, and return loss are keys to ensuring that the cabling is capable of supporting highspeed applications. Our products support damped ac dac, sinusoidal ac and cosinerectangular test technologies. The insulation resistance test is not recommended for mediumvoltage cables.
Unique combination system for cable test ing and pd diagnostics. A 1,000 volt dc megger test shall be performed on buses, motor starters, circuit breakers, and disconnect switches. Equipment for cable fault location, testing and diagnostics. Megger makes electrical test equipment to help you install, improve efficiency and extend the life of assets and cable networks at high, medium and low voltage. It should correspond to the length derived from the length markings commonly found on the outside jacket of the. Meggar testing excerpt from prysmians wire and cable. Low voltage and high voltage cable testing electrical notes. In the above circuit, the guard is connected on top of an insulator, the line terminal is connected to the conductor, which is to be tested, and the earth pin is grounded. The first applies to new equipment or cable and can use ac or dc test voltages. Uhf pd diagnosis at high voltage cable terminations international case studies. Inspect heating cable and connections for signs of damage. Establish a safety barrier to keep anyone from touching the bare copper on the ends of the cables, as your megger will be supplying high voltage during the testing period. Typical vfs cable type construction velocity factor % velocity factor m s power paper oil filled 0.
Make sure the circuit is not reenergised whilst the instrument is connected. Commissioning test for hv underground cable up to 33kv swp sp0407. A continuity check shall be performed on motor control circuits and control panel internal wiring. When ac voltage is used, the rule of thumb is 2 x nameplate voltage. Test instruments for the maintenance of electrical power. A megger is an ohmmeter that measures resistance in the megohm scale.
Electrical test equipment power station to plug megger. At this level it is important to use test equipment that will minimize errors introduced by the test lead resistance andor contact resistance between the probe and the material being tested. Test on 11kv and 33kv cables between cores and earth. The ci cable identifier will safely identify a dead or deenergized primary cable within a group of energized or deenergized cables as well as live secondary cables including neutrals up to 240 vac 440 optional. Sep 30, 2019 megger test report template, we will accustom a great deal of parts following relation to megger test report template that you have to tolerate to your manual. Time frames very with type of test, gono go short conductor runs 30 seconds to a minute when the meter reaches a stabilized reading and or long runs of cable or busway, which can require 510 minutes. Agenda system overview system startup testing system start megger test mechanical checks electrical tests cold resistance test stabilized current test end of circuit. How insulation resistance test practical with megger test meter in urdu englishin this video we can see you that how megger tester insulation resistance test. Background the following is a summary of insulation resistance ir testing commonly referred to as megger testing of low voltage cables rated less than 5 kv, recognized by nexans. The results are professionally presented, high quality certificates and reports that comply with bs7671 appendix 6 model forms and the latest code of practice for portable appliance testing. Threephase dualvoltage motor insulation resistance testing. Length length is defined as the physical or sheath length of the cable. Lv cable megger test report format fluke insulation resistance tests up to 10kv continued from part one.
If physical damage is found, replace the damaged sections. The limitation for this test is in its interpretation of the test measurements. Megger sweden, ab, box 724 182 17, danderyd, sweden, introduction. Jan 08, 2019 in modern megger as shown in figure above these range can be selected. Minimum readings are published in neta specifications. In general the condition of insulation is unknown and appropriate periodic electrical testing is required to detect potential deterioration and avoid. Figure 1 shows a simplified measuring circuit diagram of the delta 4000 test set measuring a twowinding transformer in ust test mode. There are a variety of technologies and methods used to test the insulation of wire and cable, in. This is one of the famous methods used for the testing of resistance and it was first introduced in 1903.
To test a cable with a megger, you connect one probe to the outside of the cable and, with the power turned off, you touch the probe to the conducting wire at the point of connection. A guide to diagnostic insulation testing above 1 kv. The tdr2050 is a tough, twochannel cable fault locator for power applications. Megger testing a megger test uses a megohm meter to test the insulation properties of such things as electrical wiring, motor windings and highpower antenna mounts. Offering cativ safety and meggers unique dual case design, mit515. The name megaohm meter is classified further into the name megger.
A low resistance measurement is typically a measurement below 1. Only 15 kv rated megger test leads with plug inserts of 75 mm must only be used on the mit1525. Jun 07, 2011 an insulation resistance test shall be conducted with a volt megger. High power test and diagnostics combination for medium voltage cables. Comparing this result with the correct row of table 2 shows that our cable passes the insulation resistance test. Newly laid cables may be tested to reveal any faults arising from transportation or installation.
Pdf insulation resistance testing of low voltage cables. Heating cableheating cable testing procedures september 1 2010september 1, 2010 september 2010 1 company confidential service strategy 1. Electrical utility field testing for mediumvoltage cables. The following is a summary of insulation resistance ir testing commonly referred to as megger testing of low voltage cables rated less than 5 kv, recognized by nexans. Line terminal, guard terminal, and the earth terminal. We know we can check any cable or equipment by testing insulation and by using megger we can check insulation of any device megger. Cable problems can be generally characterized as local or global e. This test is useful for the testing of internal cable resistance. We know we can check any cable or equipment by testing insulation and by. Loop test for continuity using a megger insulation tester. Insulation resistance testing megger testing southwire. Megger developed a 10 kv unit to meet the new testing recommendations. Insulation resistance testing of low voltage cables in the. How to perform instrument transformer testing with megger mrct instrument.
Safe operation of electrical power network relies on healthy electrical insulation of all of its components. The circuit under test must be switched off, deenergised, isolated and checked to be safe before insulation test connections are made. Cables for rated voltages of 1 kv um 1,2 kv and 3 kv um 3,6 kv reference number. Lowvoltage insulation resistance ir tests, more commonly called megger tests, are particularly useful in detecting shorts in lowvoltage cables 2 kv and less. Jul 24, 2018 the reporting device that is additionally meant to create and render reports in the web will consistently be there to build the reports that you requirement for your framework. The test measures the insulation resistance between the phases andor between phase and ground. Polarization index pi test is the most commonly used. It normally involves taking readings at 1 minute and 10 minutes. Typical vfs cable type construction velocity factor % velocity factor m s power paper oil filled. Understanding insulation resistance testing pdf 0712 technical assistance 800 34391. Cable insulation and continuity test report no report. Understanding insulation testing anixter wire and cable. Apr 24, 2019 insulation resistance testing is a nondestructive test procedure. It is commonly used in the industry for acceptance testing prior to energizing the cable and for maintenance testing programs.
Cables can be highly capacitive, so testing the insulation often requires a significant power output from the test equipment. Megger invented insulation testing before the beginning of the 20th century and has continued to lead the market in innovation and technological advancement. Electrical test equipment application solutions from megger. Transformer turns ratio ttr is one of the most common test used to assess the. This test is intended for use to detect the condition of the winding inside the instrument. The reading of meter will show the insulation resistance of the conductors. For high voltage transformer high voltage machine or equipment, 5 kv range is selected to perform insulation resistance test.
Pd measurement using either vlf cosine rectangular test or damped ac voltage up to 40 or 60 kv rms datasheet pd loc partial discharge pinpointing system to precisely locate pd faults. Sheath testing for fault location water ingress caused by damaged cable sheaths is a leading cause of faults in plasticsheathed cables. Megger guide to electrical insulation testing pdf instrumart. Cable testing megger s cable test solutions are comprehensive, with a focus on portability, usability and reliability. How insulation resistance test practical with megger meter. If the installation fails the megger test and physical damage cannot be found, then the complete circuit should be removed and replaced with new roof and gutter heating cable. If you do not know the vf of the cable under test it may be possible to test a known length and adjust the vf until the distance displayed to the end of the cable is correct. Every electric wire in a facility, whether its in a motor, generator, cable.
Designed for the location of faults in electrical power supply cables, the tdr2050 is supplied with fused test leads that are rated to cat iv 600 v and are dust and weatherproof to ip54, making it ideal for working on site or in the field. Documentation hazchat onsite risk assessment sp0407r01 commissioning tests for new hv cables up to 33 kv job safety analysis sp0407r02 testing hv cables supplementary information sp0407r03. Overview of common field tests anixter wire and cable. Megger has developed its free formfiller software as part of the companys longterm commitment to making life easier and more profitable for. Aug 01, 2019 the name megaohm meter is classified further into the name megger. Surely it is not tough to discover it in this site, since we prepare a number of them that weve got given. Heating cableheating cable testing procedures september. This document will focus only on the tests that are of importance for field installers which are described as installation and maintenance tests. Insulation resistance testing of low voltage cables in the field. Like a visit to the doctors office, each test examines the test item in a different way. The megger technical library provides access to a range of additional content and resources such as technical guides, application notes and more. The first thing to check is the cable testing environment and cable preparation. So, why did we develop a 10 kv model when all other suppliers stopped at 5 kv. I perform these test at vdc after verifying no loads are connected.
Many cable test systems are therefore quite large as a result. The word megger is a registered trademark a guide to diagnostic insulation testing above 1 kv test equipment depot 800. The test voltage is connected to the hv terminal and the current is measured at the lv terminal. Dielectric absorption ratio dar test is no longer commonly performed, but may be useful for smaller motors. Test methods to be used some test methods cannot be applied to all types of cables. Insulation reading shall be recorded after applying the test voltage for about a. Insulation resistance testermegger electrician talk. A cable will be subjected to multiple tests in its lifetime including a series of tests beginning at the factory and potentially continuing throughout the lifespan of the cable.
Pdf insulation resistance testing of low voltage cables in. Since diagnostic testing is generally reserved for more critical items we normally, but not always, find that diagnostic testers have voltage outputs of 5 or 10 kv, these voltages being more suitable for testing the assets which themselves are usually medium voltage machines, cables, transformers, etc. This test involves calculating the ratio of the insulation. Jun 02, 2011 cable testing revision 1 june 2, 2011 page 2 of 8 cable testing testing represents an integral part in the life of a cable.
Wide range of megger technical guides, application notes, academic papers and product support material. Megger test report template professional templates. Megger is the expert in cable test, diagnostics and fault location, supporting you with inhouse knowledge and welltrained application engineers. Each core to ground continuitypoint to wire check with low voltage tester check correct installation of cable glands check cable identification tags check that cables, wiring, ducting, trays and fittings are complete and secured isolation test shieldarmoring to ground remarks. Chapter 11 watthour test 290 chapter 12a power cable test 298 chapter 12b seba cable test 308 other megger products you may find useful 340 what cat ratings mean 341 about megger 342 environmental care and service 344 training local to you 345 index 346. Megger cable test equipment provides access to all of the technology needed to make informed cable management decisions through the different stages of the cable s life cycle. If the cable does not pass if a cable does not pass the test the cable still may be good but additional cable evaluation should be performed.